Send an email message to Call the support line at:īe prepared to provide the serial number of the Kaleidescape server.The rack enclosure has a cool air intake at the bottom front and a hot air exhaust at the top.įor additional information, contact Kaleidescape Support. The figure below shows proper ventilation and airflow for components in a rack enclosure. If the internal surfaces of a component become coated with dust, the component will require servicing by Kaleidescape. In case of sanding or other temporary dust source, turn off the component until the dust source is removed. Refer to the Engineering Bulletins, Server Cleaning Procedures and Player Cleaning Procedures for detailed cleaning instructions.ĭo not operate the component in a dusty environment. For units installed in enclosures, inspections should be performed based on the amount of filtering provided by the enclosure but at least annually. If the component is not installed in an enclosure, the front panel and rear vents should be inspected every 4 months and cleaned if necessary, to provide adequate airflow. Vents clogged with dust can lead to temperature increase and possible damage. The component front panel filters and traps coarse dust and particles. Verify intake and exhaust vents are not obstructed by dust or particles.

kaleidescape kplayer 6000

  • Verify hot air exhaust at back and top of component.
  • Verify adequate cool air intake at front and bottom of component.
  • Maintain proper airflow path for ventilation.
  • kaleidescape kplayer 6000

    (2.5 cm) clearance in front and on sides. The rack or other enclosure doors must not reduce the air space around the component to below the specified clearance. Verify proper clearance for ventilation.Use the following guidelines when installing Kaleidescape components to ensure proper ventilation. Sum each component’s airflow from the table to determine the minimum exhaust airflow required of an installation enclosure. An installation enclosure must allow the specified airflow to easily escape the enclosure through exhaust fans or external vents. The table below specifies maximum airflow generated by internal fans in Kaleidescape components.

    Kaleidescape kplayer 6000 movie#

    Movie Player (KPLAYER-2000, KPLAYER-2500) See the section Calculating Rack Airflow in the whitepaper, A/V Installation Cooling. These specifications can be used in combination with the room temperature to calculate the required airflow. The table below specifies maximum heat output for Kaleidescape components. The operating relative humidity range (non-condensing) for all Kaleidescape components is 20% to 80% the range is 5% to 90% for storage.Īll Kaleidescape components have a maximum operating altitude of 10,000 ft (3,000 m). The storage temperature range for all Kaleidescape components is 4☏ to 140☏ ( 20☌ to 60☌). Refer to the Engineering Bulletin, Vertical Mounting of Kaleidescape Components. Some Kaleidescape components can be installed in a vertical orientation, and the maximum intake air temperature decreases for some components when mounted vertically. Speed Reader (KSPEEDREADER, KSPEEDREADER-2) (2.5 cm) of the front of the component, and at any rack enclosure air intake vents. Measure ambient air temperature within 1 in. The minimum air intake temperature for all Kaleidescape components is 41☏ (5☌). The maximum temperature of the air intake for Kaleidescape components is specified in the table below. For more best practices in designing rack enclosure cooling for A/V components, refer to the white paper, A/V Installation Cooling. This document provides environmental specifications and guidance for designing proper cooling for Kaleidescape component installations.